Title: STM32F105RBT6 Bootloader Not Responding: How to Recover Your Device

When you encounter a situation where your STM32F105RBT6 bootloader is not responding, it can be frustrating. This problem can occur for a variety of reasons, but with a methodical approach, you can resolve it and restore your device. Here's a breakdown of the issue, its causes, and how to recover your device step by step.

Possible Causes for Bootloader Not Responding:

Corrupted Bootloader Code: If the bootloader’s firmware is corrupted due to an interrupted update process, Power failure, or error during programming, it might stop responding. Incorrect Boot Configuration: The bootloader might not start if the device’s boot pins are incorrectly configured, such as the BOOT0 pin not being set to the correct value. Faulty Firmware or Application Code: If the application code running on the STM32F105RBT6 is buggy or incompatible, it might prevent the bootloader from functioning properly. Communication Issues: Sometimes, the issue might be with the communication interface (such as USART, USB, or SWD) between the device and the programmer/debugger. A bad connection or incorrect settings can prevent the bootloader from responding. Power Issues: Insufficient or unstable power supply can cause the microcontroller to behave unpredictably, including making the bootloader unresponsive.

Steps to Recover Your Device:

Step 1: Verify Boot Pin Settings (BOOT0 Pin)

BOOT0 Pin Setup: Check if the BOOT0 pin is correctly configured. It should be connected to VDD to enable bootloader mode. If BOOT0 is connected to GND, the device will start in user application mode and the bootloader won’t be activated. If BOOT0 is set to 1 (VDD), reset the device, and it should enter the bootloader.

Step 2: Check Power Supply

Ensure the STM32F105RBT6 is receiving a stable and sufficient power supply. Use a multimeter to check the voltage levels (typically 3.3V for STM32 devices). If the power supply is unstable or too low, try using a regulated power source.

Step 3: Check for Corrupted Bootloader

If you suspect the bootloader firmware is corrupted: Use STM32CubeProgrammer: This software allows you to directly communicate with the device in bootloader mode over the appropriate interface (like USB, USART, etc.). You can attempt to reflash the bootloader if it’s corrupted. Reflash the Bootloader: You may need to use a JTAG or SWD programmer (like ST-Link) to reprogram the device with a working bootloader firmware.

Step 4: Debug Communication Interface

Check the communication interface between your computer and the STM32 device: If using USB: Ensure drivers are correctly installed for STM32. If using USART: Verify the baud rate, data bits, stop bits, and parity settings match those expected by the device’s bootloader. If using SWD/JTAG: Ensure the connections are secure and that no hardware issues are affecting communication.

Step 5: Use STM32CubeProgrammer for Recovery

Download and install STM32CubeProgrammer from STMicroelectronics. Connect your STM32F105RBT6 to the computer using a compatible interface (like USB or USART). Open STM32CubeProgrammer, select the correct communication interface, and choose the "Connect" option. If the bootloader responds, you can upload a new firmware to restore functionality. If the bootloader still does not respond, try a System Memory (Bootloader) recovery using a SWD/JTAG programmer.

Step 6: Hardware Recovery (If Bootloader is Completely Unresponsive)

If none of the above methods work, you may need to use a hardware programmer (like an ST-Link or J-Link) to forcefully recover the device: Use a JTAG/SWD interface to connect the programmer to the STM32F105RBT6. Using STM32CubeProgrammer or other programming tools, erase the flash memory and reprogram it with fresh firmware.

Step 7: Reflash Application Code

After successfully restoring the bootloader and communication, re-upload the application code (the firmware you want the device to run). Ensure that the application code is compatible and doesn’t conflict with the bootloader in any way.

Conclusion:

Recovering an STM32F105RBT6 device when the bootloader is not responding can be straightforward if you follow these steps methodically. Start by checking the boot configuration and power supply, then proceed with recovery using STM32CubeProgrammer and external hardware tools. By systematically diagnosing the issue, you should be able to restore functionality to your STM32F105RBT6 and continue your development.